Warning

This page was automatically imported and has not been manually cleaned up and checked yet.

There might be strange or incorrect formatting, dead links, and other issues.

The Loto OSCxxx series are compact and portable digital storage oscilloscopes, produced by Rocktech.

Devices

ModelBandwidth (MHz)Sample Rate (MS/s by ch)USB VID/PIDNotes
Loto OSCH021002500x8312:0x8a2aRel. 2020 (250MSa just CH-A)
Loto OSC2002502000x8312:0x88012018-2019 edition
Loto OSCA02351000x8312:0x8a02
Loto OSC80225800x8312:0x8312
Loto OSC48220500x8102:0x8102
Loto BM10220500x8102:0x8102out of production
Loto OSCE02502000x8312:0x8101

|

Protocol

OSC802

Commands sent via Control Transfer to EP0. Samples buffer available on Bulk EP. List of commands (provisional):

| | |Request Type|Request|Value|Index|Data|Description| |0x80|0x33|0x00|0x00|1 byte|Start acquisition.| |0x80|0x50|0x00|0x00|1 byte|Check if acquisition buffer is ready. Write 0x21 in the data byte if ready.| |0x80|0x94|value|0x00|1 byte|Set sampling rate with value[0-3] and AC/DC for Channel 1 with value[4]. Rate values: 80MSa/s (B0000), 10MSa/s (B1000), 625KSa/s (B1100)

value[4] = 1 -> DC coupling, value[4] = 0 -> AC coupling| |0x80|0x22 0x23 0x24|value|0x00|1 byte|Set Channel 1 and Channel 2 voltage. Set AC/DC for Channel 2.| |0x80|0xE7|value|0x00|1 byte|Enable (value=1) or disable (value=0) hardware trigger on Channel 1.| |0x80|0xC5|value|0x00|1 byte|Set trigger slope up (value=1) or down (value=0).| |0x80|0x16|value|0x00|1 byte|Set trigger level (value=0-255).|

Resources